| Booth shell & height | Inline and perimeter. Inline backwalls to 8 ft in the rear half, 4 ft toward the aisle; perimeter booths to 12 ft; no hanging signs on either (2027 manual) Source ↗ | Island and larger booths. Island configurations limited to 20 ft in height where ceilings permit; larger booths limited to 12 ft (2023 rules) Source ↗ | Hall A ceiling. Hall A: 250 by 530 ft, 145,841 sq ft, ceiling 18 ft 6 in to 24 ft (venue spec guide, 2025) Source ↗ | Booth package. Every 2027 booth comes with a back wall 8 ft high, side drape 3 ft high, a booth ID sign and a directory listing Source ↗ | Raw linear space. Raw linear booths include an 8 ft draped back wall, 3 ft side rails and a 44 by 7 in two-line ID sign; open corners add $500 each (2027 pricing sheet) Source ↗ | Booth unit. 100 sq ft units, each framed in pipe and drape with a booth sign; $3,050 members, $3,750 non-members (2027) Source ↗ |
|---|
| Signs & rigging | Who hangs signs. Shepard hangs signs under 200 lb with no electrical or chain motors; heavier, lit, motorized or truss pieces go to Hi-Tech/GLP Rigging (2027 manual) Source ↗ | Hanging signs. No hanging sign on 10 by 10 or 10 by 20 ft spaces; allowed on 20 by 20 ft and larger (2022 rules) Source ↗ | Rigging point loads. Halls A to D: 500 lb per point on secondary steel, 1,000 lb on primary steel, every 10 ft; Encore approves all rigging designs (2026 guidelines) Source ↗ | Hall C rigging. Rigging items over 200 lb in Hall C need extra details sent to OCCC Rigging as soon as possible; hanging-sign drawings at least three weeks before the event, with engineer certifications Source ↗ | Shell scheme booths. Shell booths include a header sign, carpet, one track light per panel, 42 in side returns, a 42 in counter, a cafe table, four chairs and a 1,000 W outlet (2027 pricing sheet) Source ↗ | Multilevel booths. Count as structures: a city building permit, plus drawings carrying the seal of a structural engineer licensed in Arizona Source ↗ |
|---|
| The floor & the space | Flooring required. The exhibit hall is not carpeted, and every exhibitor must provide floor covering (2027 manual) Source ↗ | Exhibitor-supplied carpet. In Exhibit Center North, which covers Bartolin Hall, the exhibitor must provide floor covering or carpet for the booth (2023 rules) Source ↗ | Shell or bare floor. Up to 200 sq ft: 8 ft back wall and 3 ft side drape on bare floor; booths larger than 200 sq ft are bare floorspace only (organizer exhibitor FAQ) Source ↗ | Space rate. $49 per sq ft standard; $33 per sq ft for eligible government entities (2027) Source ↗ | Drones indoors. Drones are not permitted inside the Miami Beach Convention Center; any approved XPONENTIAL demonstration is coordinated in advance under venue and safety rules Source ↗ | Ready at opening. Space not prepared by the event opening is a no-show and forfeits payment Source ↗ |
|---|
| Hardware & demos | Tall product. A product taller than the booth limit may be allowed at show management's discretion if displayed as sold; lasers and UV lighting need facility compliance and show approval; helium tanks are banned (2027 manual) Source ↗ | Storage. Fire regulations prohibit storage in the Exhibit Center or The Broadmoor complex, except within the exhibitor's booth (2023 rules) Source ↗ | Pavilion stands. 50 sq ft pavilion booths include carpet, drape and furniture, but not power (organizer exhibitor FAQ) Source ↗ | Venue services. Utility and aerial rigging services are provided by the OCCC and ordered through its exhibitor services Source ↗ | Weapons. Weapons are prohibited at XPONENTIAL except as permitted for qualifying active-duty law enforcement officers under applicable law and venue policy Source ↗ | Drone flights and fuel. Static drones allowed; flights indoors only inside a netted Interior Flight Zone with a 5-foot keep-clear band; display vehicle tanks at or below one quarter full or 5 U.S. gallons Source ↗ |
|---|
| Setup, labor & paperwork | Exhibitor labor limits. Exhibitors may set booths of 10×20 or smaller themselves; larger booths give two employees one hour each way, then Carpenters Local 491; no power tools (2027 manual) Source ↗ | Set-up deadline. Booths set by 3:00 pm Monday of Symposium week; unset space is set up by Freeman and billed to the exhibitor (2023 rules) Source ↗ | Reuse rating. Space-only stands rated disposable, bronze, silver or gold by reuse; 2027 exhibitors asked to reach at least bronze (Better Stands) Source ↗ | Move-in windows. January 11 from 9 a.m. until 5 p.m., then January 12 from 7 to 10:30 a.m., with the expo opening at noon Source ↗ Badges. Three badges per 100 sq ft, plus two for each additional 100 sq ft Source ↗ | AV labor. Staging, production and audio-visual work at the venue is done by union labor under agreements with IATSE Locals 500 and 600 and IBEW (venue FAQ) Source ↗ Export control. Participants are responsible for compliance with the EAR and ITAR for export-controlled technology, technical data and defense services shown at the event Source ↗ | Liability insurance. Certificate or affidavit with at least $1,000,000 general liability due by April 12, 2027 Source ↗ |
|---|