Fountains and palm trees along the entrance drive outside the Santa Clara Convention Center, with low office buildings beyond

Exhibitor guide · Santa Clara, CA · Updated

Santa Clara Convention Center Exhibitor Guide

Also known as SCCC

Silicon Valley's chip, sensor and developer shows meet in four halls of about 90,000 sq ft, joined to the Hyatt Regency and a short walk from Levi's Stadium. The building is small enough to learn in a day. The things that trip exhibitors up are parking on stadium days, a strict freight policy and Bay Area union rules.

  • 3,000+ exhibitors served
  • 10,000+ booths built
  • 2 days to a design brief

Photo: the fountain drive seen from the convention center during a 2007 conference. “View from Santa Clara Convention Center (MySQL Conference 2007)” by oswaId, CC BY 2.0. Source

  • 90,014sq ft in exhibit Halls A to D
  • 28′6″hall ceiling, with a 20 ft soffit between halls
  • 22,400sq ft Mission City Ballroom, opened 2009
  • 31breakout rooms, plus a 607-seat theater
  • 1,500garage spaces shared with the Hyatt and TechMart
  • ~505rooms at the connected Hyatt Regency

Quick answers

What exhibitors ask about the Santa Clara Convention Center

Is the Santa Clara Convention Center union?Yes.

California is not a right-to-work state. The center's guide lists Teamsters Local 853 for freight, Sign & Display Local 510 for booth work, IATSE Local 134 for AV and rigging, and IBEW Local 332 for electrical.

Can my own staff set up our booth?Usually only small jobs.

The center's guide says the union rules allow self-setup only without hand tools, by one person, in 30 minutes. Some show kits allow more, so your kit decides.

Can I unload my own vehicle?Hand-carry only.

Park in the garage and wheel small items to the dock by ramp, or carry them through the lobby. There is no loading at the front circle.

What is the ceiling height?28′6″ in the halls.

That is the figure in a 2022 show kit for Halls C and D. The soffit between halls drops to 20 ft. Fire approval is needed for booths over 12 ft.

Photos: "CHP 5.0 Mustang DSC_1015" by wbaiv, CC BY-SA 2.0 Source · "bike racks at Levi's Stadium" by Richard Masoner / Cyclelicious, CC BY-SA 2.0 Source · "Linux Foundation Open Networking Summit" by linux_foundation, CC BY 2.0 Source

A packed Levi's Stadium in red seats around the 49ers field on opening day, seen from the upper stands
Levi's Stadium on its 2014 opening day. On game days its crowds and parking reach the convention center's front door. “Levi's stadium opening” by Jim Bahn, CC BY 2.0. Source
Only at the Santa Clara Convention Center

Santa Clara Convention Center and Levi's Stadium: planning around stadium days

The convention center, the Hyatt Regency and the TechMart share one campus and one garage, a short walk from Levi's Stadium and across from California's Great America. On a big stadium day, the stadium crowd competes for the same roads and parking as your show. Check the stadium calendar before you set move-in and staff travel.

  • 1,500spaces in the garage shared with the Hyatt and the TechMart. Parking is listed as free, but the center says it cannot guarantee spaces during major events at Levi's Stadium, and fees may apply.
  • 0marshaling yards. The center no longer has one. Your contractor may need an off-campus lot, and trucks may not wait on city streets.
  • 2rail stops next door: the VTA Great America light rail station and the Santa Clara–Great America station for ACE and Amtrak trains. Staff can leave the car at the hotel.
  • 2014Levi's Stadium opened next door. That year the 49ers agreed not to use convention parking on NFL game days through February 2016; we found no newer public agreement.

Sources: SCCC parking and directions page; SCCC Facilities Guide 2026–2027 (parking and marshaling); Wikipedia; Silicon Valley Voice (2014 parking agreement).

Where to stay & getting there

Hotels near Santa Clara Convention Center

One hotel connects straight to the center: the Hyatt Regency Santa Clara, with about 505 rooms, on the same campus and garage. The Hilton Santa Clara faces the center from across the street. We do not have published walking times, so ask your hotel for the best route.

Connected · same campus

Hyatt Regency Santa Clara

About 505 rooms at 5101 Great America Parkway, joined to the convention center and close to Levi's Stadium.

Across the street

Hilton Santa Clara

At 4949 Great America Parkway, facing the center.

On campus

Convention center garage

About 1,500 spaces shared with the Hyatt and the TechMart, with a bridge from level 3 into the building.

Next door

VTA and ACE trains

Great America light rail station and the Santa Clara–Great America station for ACE and Amtrak.

About 5–6 mi

SJC airport

San José Mineta International is the closest airport. The center says three airports lie within 5 to 37 miles.

Floor plan & exhibit halls

Santa Clara Convention Center floor plan: Exhibit Halls A to D

Four halls of similar size sit side by side and combine into 90,014 sq ft. Hall A can split into three parts for small expos. The center says its standard layout suits 10×10 booths with a double back wall lined up on the floor boxes. The diagram shows the four halls, the 20 ft soffit where halls join, and what each dock serves.

Exhibit Halls A to D, Santa Clara Convention Center (schematic, not to scale)Schematic of the four exhibit halls, A to D, side by side, 90,014 sq ft combined. Hall A: 22,758 sq ft, splits into A1 (10,676 sq ft), A2 (5,834) and A3 (6,250), 1,800 theater seats, served by the Dock 3 ramp. Hall B: 23,604 sq ft, the largest single hall. Hall C: 21,826 sq ft, freight door 18 ft 8 in by 16 ft. Hall D: 21,826 sq ft. A 2022 show kit lists Halls C and D at a 28 ft 6 in ceiling and 250 lbs per sq ft, with a 20 ft soffit where two halls join. Booths over 12 ft need fire department approval. Combinations: A and B 46,362 sq ft; B and C 45,430; C and D 43,652; A to C 68,188; B to D seat 5,400 theater style. Docks from the 2020 dock map: Docks 5 to 12 behind the halls, a ramp at Dock 3 for Hall A, Dock 2 for the Hyatt and Grand Ballroom side, reached from Tasman Drive and Bunker Hill Lane; trucks stage in the yellow freight area on the back road. Mission City Ballroom 22,400 sq ft with 2,100 theater seats. Great America Ballroom 6,264 sq ft. 31 breakout rooms and a 607-seat theater. Hyatt Regency Santa Clara, about 505 rooms, connected. Garage of about 1,500 spaces with a bridge from level 3. Levi's Stadium next door.SIDE VIEW · CEILING, HALLS C AND D (2022 SHOW KIT)SCHEMATIC, NOT TO SCALE28′6″Hall C28′6″Hall D20 ft soffit12 ft · fire approval lineHalls A and B: ceiling not listed in that kitPLAN · EXHIBIT HALLS A TO D, SIDE BY SIDEA22,758 sq ftsplits into A1 · A2 · A31,800 theater seatsDock 3 rampB23,604 sq ftlargest single hallC21,826 sq ft28′6″ · 250 lb/sq ft2022 show kitdoor 18′8″ × 16′D21,826 sq ft28′6″ · 250 lb/sq ft2022 show kit90,014 sq ft with all four halls · B to D seat 5,400DOCKS · 2020 DOCK MAP · ACCESS FROM TASMAN DR AND BUNKER HILL LNDocks 5 to 12 · 8 docksBehind the exhibit hallsDock 3 · rampFor Hall ADock 2Hyatt and Grand Ballroom sideTruck stagingYellow freight loading areaon the back road; no waitingon city streetsELSEWHERE ON THE CAMPUS · NOT DRAWN WHERE THEY SITMission City Ballroom22,400 sq ft · opened 20092,100 theater seatsRigging points 1,000 lb eachGreat America Ballroom6,264 sq ftIn the 1995 Great America wing31 breakout roomsPlus a 607-seat theaterHyatt Regency · connectedAbout 505 rooms5101 Great America PkwyGarage · about 1,500 spacesShared with the Hyatt and TechMartBridge into the building from level 3Levi's Stadium · next doorGarage parking not guaranteedduring major stadium eventsRail stations · next doorVTA Great America light railACE and Amtrak station Exhibit Halls A to D, Santa Clara Convention Center (schematic, not to scale)Schematic of the four exhibit halls, A to D, side by side, 90,014 sq ft combined. Hall A: 22,758 sq ft, splits into A1 (10,676 sq ft), A2 (5,834) and A3 (6,250), 1,800 theater seats, served by the Dock 3 ramp. Hall B: 23,604 sq ft, the largest single hall. Hall C: 21,826 sq ft, freight door 18 ft 8 in by 16 ft. Hall D: 21,826 sq ft. A 2022 show kit lists Halls C and D at a 28 ft 6 in ceiling and 250 lbs per sq ft, with a 20 ft soffit where two halls join. Booths over 12 ft need fire department approval. Combinations: A and B 46,362 sq ft; B and C 45,430; C and D 43,652; A to C 68,188; B to D seat 5,400 theater style. Docks from the 2020 dock map: Docks 5 to 12 behind the halls, a ramp at Dock 3 for Hall A, Dock 2 for the Hyatt and Grand Ballroom side, reached from Tasman Drive and Bunker Hill Lane; trucks stage in the yellow freight area on the back road. Mission City Ballroom 22,400 sq ft with 2,100 theater seats. Great America Ballroom 6,264 sq ft. 31 breakout rooms and a 607-seat theater. Hyatt Regency Santa Clara, about 505 rooms, connected. Garage of about 1,500 spaces with a bridge from level 3. Levi's Stadium next door.PLAN · HALLS A TO DSCHEMATIC, NOT TO SCALEA22,758 sq ftsplits into A1 · A2 · A31,800 theater seatsDock 3 rampB23,604 sq ftlargest single hallC21,826 sq ft28′6″ · 250 lb/sq ft2022 show kitdoor 18′8″ × 16′28′6″ceilingD21,826 sq ft28′6″ · 250 lb/sq ft2022 show kit28′6″ceilingA and B:ceiling notin the kit90,014 sq ft with all four hallsC, D: 28′6″, 20 ft soffit at join (2022 kit).Booths over 12 ft need fire approval.DOCKS · 2020 DOCK MAPDocks 5 to 12 · 8 docksBehind the halls · Tasman Dr and Bunker Hill LnDock 3 · rampFor Hall ADock 2Hyatt and GrandBallroom sideTruck stagingYellow freight area on the back roadALSO ON THE CAMPUSMission CityBallroom · 22,400 sq ft2,100 theater seatsGreat AmericaBallroom · 6,264 sq ft1995 wing31 breakout roomsPlus a 607-seattheaterHyatt RegencyConnectedAbout 505 roomsGarage · about 1,500 spacesShared with Hyatt and TechMart · level 3 bridgeNot guaranteed on major Levi's Stadium days
  • Hall divider; halls combine
  • 20 ft soffit where two halls join

Schematic, not to scale: hall widths follow floor area from the center's floor plan and capacity sheet. Ceiling, soffit, floor load and the Hall C door come from a 2022 show kit for Halls C and D. Dock positions, the ballrooms and the hotel are not drawn where they really sit. Official floor plans and the dock map are on santaclaraconventioncenter.com.

Exhibit Halls A to D, hall by hall
HallFloor areaSplitsCeilingTheater seatsAccess
A22,758 sq ftA1 10,676 · A2 5,834 · A3 6,250not listed1,800Dock 3 ramp
B23,604 sq ft–not listed––
C21,826 sq ft–28′6″–Door 18′8″ × 16′
D21,826 sq ft–28′6″––
  • A + B46,362 sq ft
  • B + C45,430 sq ft
  • C + D43,652 sq ft
  • A to C68,188 sq ft
  • B to D5,400 theater seats
  • A to D90,014 sq ft

Hall sizes, splits, combinations and seating from the center's 2023 floor plans and capacity sheet. The 28′6″ ceiling, 20 ft soffit and 250 lbs per sq ft floor load are from a 2022 show kit for Halls C and D; the center publishes no ceiling height for Halls A and B in the documents we found.

90,014sq ft in Halls A–D combined · 250 lbs per sq ft concrete floors (2022 kit)
22,400sq ft Mission City Ballroom, opened 2009 · 2,100 theater seats · rigging points rated 1,000 lb each
6,264sq ft Great America Ballroom, in the 1995 Great America wing
31breakout rooms, plus a 607-seat theater

Loading dock & move-in

Santa Clara Convention Center loading dock and freight

Get directions to Santa Clara Convention Center →

  • DocksThe center's dock map shows Docks 5 to 12 behind the halls, a ramp at Dock 3 for Hall A, and Dock 2 for the Hyatt and Grand Ballroom. Access is from Tasman Drive and Bunker Hill Lane. Your event manager sets load-in times.
  • Truck stagingCommercial trucks wait in the signed yellow freight loading area on the back road before backing in. Vehicles left at a dock are cited or towed.
  • All freight by dockOnly hand-carried items may come through the front entrance. Everything else must cross the docks or the roll-up doors in the exhibit halls.
  • Hand-carry routeThe center suggests parking in the southeast corner of garage level 1 and wheeling to the dock by ramp. Small items can also come over the bridge from garage level 3. Under a union decorator you may be required to use their labor to unload.
  • No advance freightThe center does not accept freight for exhibitions. Shipments that arrive before the first move-in day are refused and the client is charged a fee. Ship to your decorator's warehouse.
  1. Day −60Booth over 12 ft, a canopy or a double-deck? Plan for Santa Clara Fire Department approval. Covered booths over 1,000 sq ft need sprinklers.
  2. Day −35Rigging plot to Pinnacle Live at least 21 days before load-in; earlier is better. Power ordered from the show's electrical contractor.
  3. Day −30Freight booked to the decorator's advance warehouse, never to the center.
  4. Day −21Purple ships to Santa Clara through our carrier network.
  5. Day 0Trucks to the yellow staging area, then the dock. Cars to the garage. Check for stadium events.
  6. Show +1Move-out. Crates come back from storage; nothing is left at the docks.

Labor & union rules

Santa Clara Convention Center union rules: what your team can do itself

California is not a right-to-work state. The center's 2026–2027 Facilities Guide names a union for each kind of work, from freight to signs. It also states the general rule: no self-setup that needs hand tools, more than one person or more than 30 minutes. Some show kits are more generous, so read yours before you staff the booth.

✓Your full-time staff

  • Set up an exhibit that needs no hand tools, one person and 30 minutes or less (center's guide)
  • Bring hand-carried items to the booth yourself
  • Some kits allow more: a 2022 TotalExpo kit here let full-time employees do all booth work, with company ID
  • Move your own items on a hand truck where the kit allows; pallet jacks were banned in that kit

●Union labor and exclusives

  • Teamsters Local 853: freight to and from the booth
  • Sign & Display Local 510: booth install and dismantle, carpet, drape, signs, graphics
  • IATSE Local 134: AV, lighting and rigging, through Pinnacle Live
  • IBEW Local 332: electrical, by a licensed contractor named for your show
  • Pinnacle Live: exclusive rigger; the decorator may hang signs up to 100 lb
  • Smart City: exclusive internet · Levy: exclusive food and beverage

!Never allowed

  • Loading or unloading at the front circle of the building
  • Freight through the front entrance
  • Freight shipped to the center before move-in
  • Trucks waiting on city streets
  • Outside food; samples must be bought from Levy
  • Your own AV company rigging from the ceiling

Background photo: "Linux Foundation Open Networking Summit" by linux_foundation, CC BY 2.0 Source

Free tool · plan your Santa Clara budget

Santa Clara Convention Center drayage and show budget estimator

Pick a booth size and type to get planning numbers for shipping weight, drayage at about $160 per hundredweight, a Bay Area union rate a little below downtown San Francisco, and installation and dismantling (I&D) labor. Every number is a Purple planning estimate, not a quote. The center publishes no drayage or labor rate, and the newest public base rate we found nearby is old: $108.25 crated to the warehouse in a 2018 GES kit in San Jose. Your general contractor's show kit carries the actual tariff. See all venues on the drayage rates page.

Booth size
Booth type

The fields below fill in from size and type. Change any of them.

Packaging

Purple planning estimate · not a quote

Drayage + I&D labor, Santa Clara

$5,090 – $8,680
Shipping weight planning estimate
1,800 lbs
Drayage planning estimate
$2,880
I&D labor hours planning estimate
16 – 28 hrs
I&D labor planning estimate
$2,210 – $5,800

18 cwt at $160 per 100 lbs. Labor at $138–$207 per hour, straight time.

Get a real Santa Clara quote

How these planning numbers work

  • Shipping weight: about 6 lbs per sq ft for a rental booth, 9 for custom or hybrid, 12 for fully custom, crated, with graphics and furniture.
  • Drayage: $160 per 100 lbs (cwt), Purple's Santa Clara planning rate, with a 200 lb minimum. Loose or pad-wrapped freight adds 30%.
  • I&D labor hours: install plus dismantle, 0.06–0.10 person-hours per sq ft for rental, 0.08–0.14 for custom or hybrid, 0.12–0.20 for fully custom.
  • Labor rate: $138–$207 per person-hour, straight time, a planning range from published 2026 show labor rates elsewhere. No Santa Clara rate is published, and overtime costs more.
  • Own staff: only if this venue's rules and your show kit let your own full-time staff set up (see the labor section above). Then, I&D labor drops to $0 here.
  • Not included: booth space, the exhibit itself, freight to Santa Clara, power and internet orders, rigging, travel and tax.

Santa Clara notes: California is not a right-to-work state, and Bay Area unions cover freight (Teamsters Local 853) and booth work (Sign & Display Local 510). The center's 2026–2027 guide allows self-setup only without hand tools, by one person, in 30 minutes; a 2022 show kit here let full-time employees do all booth work. Tick the own-staff box only if your kit says so. Rigging over the decorator's 100 lb limit goes to Pinnacle Live and is not included.

A crowd of DEMO Spring 2012 attendees mingling on a sunny palm-lined patio in Santa Clara

Networking at DEMO Spring 2012

Startup launches inside, then the crowd moves out into the Santa Clara sun between sessions.

Photo: "DEMO Spring 2012" by Kevin Krejci, CC BY 2.0 Source

The calendar

Santa Clara Convention Center events 2026–2027: trade and consumer shows

This is where Silicon Valley's hardware engineers exhibit: signal integrity, chiplets, sensors and memory. Confirm dates, halls and contractor with each organizer.

Dates from each organizer; DeveloperWeek dates from its speaker call. The FMS page also shows July 28–30 in one place, so confirm. Consumer shows such as Sneaker Con Bay Area (November 7–8, 2026) fill weekends. Three tech events leave in 2027: the Embedded Vision Summit joins Photonics West in San Francisco, and AI Infra Summit and IoT Tech Expo North America move to the San Jose McEnery Convention Center.

The building

From Apple's first WWDC to Silicon Valley's chip shows

The city of Santa Clara built its convention center in the mid-1980s, as the valley's tech companies needed a place to meet. It still hosts their engineers today.

A swing carousel ride under autumn trees at California's Great America amusement park in Santa Clara
California's Great America, the theme park beside the convention center. “Great America, Santa Clara” by mliu92, CC BY-SA 2.0. Source
The empty red seating bowl and green field of Levi's Stadium in Santa Clara
“Levi's Stadium, Santa Clara, CA” by jimg944, CC BY 2.0. Source
The white facade and bell tower of Mission Santa Clara de Asís behind a round flower bed and palm trees
Mission Santa Clara de Asís, the city's namesake, on the Santa Clara University campus. “Mission Santa Clara de Asis (1) - 2011-08-31” by 4nitsirk, CC BY-SA 2.0. Source
  1. 1986The center is completed, owned by the City of Santa Clara.
  2. 1987Apple holds its first Worldwide Developers Conference here.
  3. 1995The Great America wing is completed.
  4. 2009The 22,400 sq ft Mission City Ballroom opens in July.
  5. 2014Levi's Stadium opens next door.
  6. 2019Spectra takes over operations from the Santa Clara Chamber of Commerce in March.
  7. 2020The center serves as a federal medical station during COVID-19.
  8. 2021Oak View Group buys Spectra and now manages the center for the city.
  9. 2023The Silicon Valley Auto Show starts its run here.

Insider tips

Santa Clara Convention Center exhibitor tips: what experienced teams do

Parking

Check the Levi's calendar first

The center cannot guarantee garage parking during major stadium events. If a game or concert falls on move-in or a show day, send staff by light rail from the hotel.

Freight

Never ship to the building

Freight that reaches the center before move-in is refused, and a fee is charged. Ship to the decorator's warehouse or time a direct truck for your target slot.

Rigging

Keep hanging signs under 100 lb

The decorator may hang signs up to 100 lb. Heavier signs and chain motors go to Pinnacle Live, the exclusive rigger, and the rigging plot is due 21 days before load-in.

Fire rules

Over 12 ft means the fire department

Santa Clara Fire must approve booths over 12 ft tall, canopies and double-decks, and covered areas over 1,000 sq ft need sprinklers. Build that into your timeline.

Halls

Mind the 20 ft soffit

The halls are 28′6″, but the soffit where two halls join drops to 20 ft. In a combined-hall show, ask whether your booth sits under it before you design a tall structure.

Docks

Unload from the garage, not the door

There is no loading at the front circle. Park in the southeast corner of garage level 1 and wheel small items to the dock, or use the bridge from level 3.

FAQ

Santa Clara Convention Center FAQ for exhibitors

How big is the Santa Clara Convention Center?

Its four exhibit halls, A to D, total 90,014 sq ft. Hall B is the largest at 23,604 sq ft. There is also the 22,400 sq ft Mission City Ballroom, 31 breakout rooms and a 607-seat theater.

Is the Santa Clara Convention Center union?

Yes. California is not a right-to-work state. The center's guide lists Teamsters Local 853 for freight, Sign & Display Local 510 for booth install, IATSE Local 134 for AV and rigging, IBEW Local 332 for electrical and UNITE HERE Local 19 for food and beverage.

Can I set up my own booth at the Santa Clara Convention Center?

The center's guide says the union rules generally allow it only if the work needs no hand tools, one person and 30 minutes or less. Some show kits allow full-time employees to do more. Your show kit has the final word.

Where is the loading dock?

Behind the exhibit halls, reached from Tasman Drive and Bunker Hill Lane. The center's dock map shows Docks 5 to 12, a ramp for Hall A and a dock for the Hyatt side. Trucks wait in the yellow freight area on the back road.

Can I unload from my own car?

Only hand-carried items. Park in the garage, ideally the southeast corner of level 1, and wheel items to the dock by ramp. There is no loading at the front circle, and a union decorator may require its own labor.

How much is drayage at the Santa Clara Convention Center?

Plan about $160 per hundredweight for crated freight. The center does not set drayage; your show's general contractor does, in its show kit.

What is the ceiling height?

28′6″ in Halls C and D, per a 2022 show kit, with a 20 ft soffit between halls. Booths over 12 ft need fire department approval.

Who supplies power and internet?

Internet is exclusive to Smart City Networks. Electrical is not a venue exclusive: your show names a licensed electrical contractor, usually ordered through the show kit.

Is parking free?

The garage is listed as free, but the center cannot guarantee parking during major events at Levi's Stadium, and fees may apply then. There is no reserved parking.

How far is it from San Jose and the airport?

SJC airport is about 5–6 miles away. The larger San Jose McEnery Convention Center is in downtown San Jose, a short drive south.

Exhibiting in Santa Clara?

Send your hall, your height and your show dates.

Tell us your show, hall and booth size, and how tall you want to build. Within two business days you get a design brief that fits the 28′6″ halls and the 12 ft fire rule, a drayage estimate at Bay Area rates and a move-in plan that checks the stadium calendar.

Background photo: "Gold Striker, Great America, Santa Clara" by mliu92, CC BY-SA 2.0 Source

Compare venues

Santa Clara Convention Center vs other major U.S. convention centers

How the Santa Clara Convention Center stacks up against other big-city halls we have guides for. Drayage figures are Purple planning rates, not published tariffs.

VenueTypeLargest spaceCeilingLaborDrayage (plan)Airport
Santa Clara Convention CenterThis guideConvention center90,014 sq ft Halls A–D28 ft 6 inUnion · check kit≈ $160/cwtSJC · 5–6 mi
America's Center Convention ComplexSt. LouisConvention center574,000 sq ft contiguous, with Dome floor40 ftUnion · 300 sq ft rule≈ $150/cwtSTL · 14 mi
Anaheim Convention CenterAnaheimConvention center221,284 sq ft Hall D25 ft Hall D · 13 ft 8 in Hall EUnion · check kit≈ $172/cwtSNA · 13 mi
Boston Convention & Exhibition CenterBostonConvention center516,000 sq ft contiguous (Halls A–C)35 ft low · up to 100 ftUnion · staff setup OK≈ $324/cwtBOS · 3 mi
Calvin L. Rampton Salt Palace Convention CenterSalt Lake CityConvention center515,000 sq ft contiguous, 10 halls30 ftRight-to-work≈ $120/cwtSLC · ~6 mi
Charlotte Convention CenterCharlotteConvention center280,000 sq ft contiguous, Halls A–C30 ft listed maxRight-to-work≈ $115/cwtCLT · 7 mi
Fontainebleau Las VegasLas VegasResort ballrooms105,264 sq ft Royal Ballroom28 ft 10 inUnion · check kit≈ $185/cwtLAS · 4.3 mi
Georgia World Congress CenterAtlantaConvention center1M+ sq ft contiguous (Halls B, BC, C)30 ft to gridRight-to-work≈ $150/cwtATL · 15–20 min
Huntington PlaceDetroitConvention center623,000 sq ft contiguous, Halls A–D30 ft (A–D) · 18 ft 8 in (E)Union · 400 sq ft rule≈ $155/cwtDTW · 20 mi
Iowa Events CenterDes MoinesConvention center150,000 sq ft contiguous, EMC Expo Center Halls A–C35 ft (Halls B–C)Right-to-work≈ $100/cwtDSM · ~10 min
Javits CenterNew YorkConvention center~500,000 sq ft contiguous (Level 3)Varies by hall · check planUnion · 250 sq ft rule≈ $195/cwtEWR / LGA / JFK · 45–70 min
Kansas City Convention CenterKansas CityConvention center388,800 sq ft column-free, Bartle Hall A–E33 ft A–C · 42 ft D–EIATSE 31 · check kit≈ $145/cwtMCI · ~19 mi
McCormick PlaceChicagoConvention center840,000 sq ft Hall A (South) · 1.2M+ on one levelVaries by hall · check planUnion · staff setup any size≈ $210/cwtMDW · ~20 min
Minneapolis Convention CenterMinneapolisConvention center376,200 sq ft contiguous, Halls B–E30 ft 6 in to truss · 85 ft domesUnion · open dock≈ $150/cwtMSP · ~20 min
Moscone CenterSan FranciscoConvention center502,440 sq ft contiguous, Halls A–F37 ft Halls A–C · 28 ft Hall FUnion · check kit≈ $180/cwtSFO · 25–40 min
Oklahoma City Convention CenterOklahoma CityConvention center200,730 sq ft continuous, up to 4 halls30 ftRight-to-work≈ $105/cwtOKC · ~9–10 mi
Orange County Convention CenterOrlandoConvention center1,103,538 sq ft West Building30–40 ftRight-to-work≈ $155/cwtMCO · 12 mi
Oregon Convention CenterPortlandConvention center255,000 sq ft Halls A–E30 ftUnion · check kit≈ $150/cwtPDX · MAX ~30 min
San Diego Convention CenterSan DiegoConvention center525,701 sq ft contiguous, Halls A–H27 ft 4 in A–E · up to 64 ft F–HUnion · check kit≈ $176/cwtSAN · 3 mi
San Jose McEnery Convention CenterSan JoseConvention center143,000 sq ft Halls 1–332 ftUnion · 30 min / 10 ft rule≈ $160/cwtSJC · 4 mi
Seattle Convention CenterSeattleConvention center205,700 sq ft Arch Halls 4A–4F25 ft Arch · 30 ft SummitUnion · check kit≈ $165/cwtSEA · Link ~40 min

More California guides

Other convention centers near Santa Clara

All venue guides →

Written by the Purple Exhibits team. Reviewed for the 2026–2027 season. Figures marked for verification are being confirmed with the venue. Sources: Santa Clara Convention Center Facilities Guide 2026–2027, floor plans and capacity sheet (2023), dock map and parking page, the CACM 2022 exhibitor service manual (TotalExpo) and Sensors Converge 2026 show information (GES), Discover Santa Clara, Silicon Valley Voice, Pollstar, Meetings Today, Wikipedia, and organizer sites for DesignCon, DeveloperWeek, the Silicon Valley Auto Show, Chiplet Summit, Sensors Converge and FMS.