The stone and glass corner of the Walter E. Washington Convention Center on a sunny day, with a tall glass atrium, a red bus and cars at the intersection in front

Exhibitor guide · Washington, DC · Updated

Walter E. Washington Convention Center Exhibitor Guide

Also known as WEWCC and the Washington Convention Center, the name it opened under in 2003

Washington's convention center stacks its 703,000 sq ft of exhibit space on two levels: Halls A, B and C below the street, Halls D and E above it, each with its own truck entrance on M Street. It is a union floor, where Teamsters move freight and Carpenters, stagehands and electricians own most booth work, so check what your own staff may do before you pack the tools.

  • 3,000+ exhibitors served
  • 10,000+ booths built
  • 2 days to a design brief

Photo: the convention center from the street. “Walter E. Washington Convention Center” by ajay_suresh, CC BY 2.0. Source

  • 703,000sq ft of exhibit space in five halls
  • 473,000sq ft contiguous in Halls A–C on the lower level
  • 52 ft 9 intop ceiling height in Halls D–E; A–C mostly 30 ft
  • 59docks: 39 for A–C, 20 for D–E
  • 350lb per sq ft floor load in every exhibit hall
  • 1,175rooms at the Marriott Marquis, linked underground

Quick answers

What exhibitors ask about the Walter E. Washington Convention Center

Is the WEWCC union?Yes, union jurisdictions.

A 2026 show kit lists Teamsters Local 639 for freight, Carpenters Local 491 for booth building, IATSE Local 22 for rigging and IBEW Local 26 for electrical.

Can my staff build our booth?Depends on the show's contractor.

Some DC kits let full-time employees set up any size booth; others allow only hand-carried, no-power-tool work. Use the checker and read your kit.

Which dock do I use?7th & M for A–C, 9th & M for D–E.

Trucks enter eastbound on M Street. Dock hours are 6 a.m. to 9 p.m., and the show's contractor assigns your bay.

Is a hotel connected?Yes, the Marriott Marquis.

The 1,175-room hotel links to the center by an underground concourse under 9th Street NW.

Photos: "20220903SM2530" by Library of Congress Life, CC0 Source · "Awesome Con DC 2015" by SPakhrin, CC BY 2.0 Source · "Chinatown - Washington, DC" by soomness, CC BY 2.0 Source

Floor plan & exhibit halls

Walter E. Washington Convention Center floor plan: the exhibit halls on two levels

The building spreads over several city blocks and five levels. The big exhibit floor, Halls A, B and C, sits on the lower level and combines into 473,000 sq ft. Halls D and E are a separate 230,000 sq ft floor on Level 2, with far higher ceilings and a 180 ft clear span. The 52,000 sq ft ballroom is on Level 3. Each exhibit level has its own docks and truck entrance, so ask which hall you are in before you book freight.

Walter E. Washington Convention Center exhibit levels, Washington, DC (schematic, not to scale)Stacked schematic of the Walter E. Washington Convention Center. Level 3: Ballroom A, B and C, 52,000 sq ft, 40 to 48 ft ceiling. Level 2: Halls D and E, 111,000 and 119,000 sq ft, 230,000 sq ft contiguous, about 1,000 ten-by-ten booths, ceiling 40 ft to 52 ft 9 in, 180 ft clear span, 20 covered docks reached from the 9th and M Street dock entrance, drive-in doors 16 by 15 ft in Hall D and 20 by 15 ft in Hall E. Street level: grand lobby, registration and the East and West Salons, 40,000 sq ft. Concourse level: show offices and escalators down to Halls A to C. Lower level: Halls A, B and C, 151,000, 194,000 and 128,000 sq ft, 473,000 sq ft contiguous, about 2,500 booths, ceiling mostly 30 ft, columns mostly on 90 ft centers, 39 enclosed docks reached from the 7th and M Street dock entrance, 3 drive-in doors 25 by 15 ft and 2 overhead doors 19 by 15 ft. Floor load 350 lb per sq ft in all halls. Figures from the Events DC floor plan book (2011).SECTION · FIVE LEVELS, TOP TO BOTTOMSCHEMATIC, NOT TO SCALELevel 3ballroomBallroom A · B · C52,000 sq ft · 40–48 ft ceilingLevel 2Halls D–ED111,000 sq ftE119,000 sq ftD–E 230,000 sq ft · ~1,000 booths · 40 ft to 52 ft 9 in · 180 ft clear span20 covered docks10 for D, 10 for ETruck entry 9th & M StDrive-ins: D 16×15 ft,E 20×15 ft + overhead20×15 ftLevel 1streetGRAND LOBBY · REGISTRATION · EAST & WEST SALONS 40,000 SQ FTHand carry: 9th & Mt Vernon PlLevel CconcourseSHOW OFFICES · ESCALATORS DOWN TO HALLS A–CLevel LHalls A–CA151,000 sq ftB194,000 sq ftC128,000 sq ftA–C 473,000 sq ft · ~2,500 booths · mostly 30 ft · columns on 90 ft centers39 enclosed docksfor Halls A, B and CTruck entry 7th & M St3 drive-in doors 25×15 ft2 overhead doors 19×15 ft12 ft zone: south sideof Hall A (10,000 sq ft)IN EVERY HALLFloor load 350 lb/sq ftall exhibit halls(2011 floor plan book)Floor boxes, 30 ft gridpower, voice and dataIBEW Local 26 connectsFreight: Teamsters 639dock to boothunion crews unload POVsMarriott Marquis1,175 roomsunderground concourse Walter E. Washington Convention Center exhibit levels, Washington, DC (schematic, not to scale)Stacked schematic of the Walter E. Washington Convention Center. Level 3: Ballroom A, B and C, 52,000 sq ft, 40 to 48 ft ceiling. Level 2: Halls D and E, 111,000 and 119,000 sq ft, 230,000 sq ft contiguous, about 1,000 ten-by-ten booths, ceiling 40 ft to 52 ft 9 in, 180 ft clear span, 20 covered docks reached from the 9th and M Street dock entrance, drive-in doors 16 by 15 ft in Hall D and 20 by 15 ft in Hall E. Street level: grand lobby, registration and the East and West Salons, 40,000 sq ft. Concourse level: show offices and escalators down to Halls A to C. Lower level: Halls A, B and C, 151,000, 194,000 and 128,000 sq ft, 473,000 sq ft contiguous, about 2,500 booths, ceiling mostly 30 ft, columns mostly on 90 ft centers, 39 enclosed docks reached from the 7th and M Street dock entrance, 3 drive-in doors 25 by 15 ft and 2 overhead doors 19 by 15 ft. Floor load 350 lb per sq ft in all halls. Figures from the Events DC floor plan book (2011).FIVE LEVELS, TOP TO BOTTOMNOT TO SCALELevel 3 · Ballroom A · B · C52,000 sq ft · 40–48 ft ceilingLevel 2 · Halls D–ED111,000sq ftE119,000sq ft230,000 sq ft · 40 ft to 52 ft 9 in20 covered docks · trucks at 9th & M StDrive-ins: D 16×15 ft, E 20×15 ftLevel 1 · streetLobby, registration, salons · hand carryLevel C · concourseShow offices · escalators to Halls A–CLevel L · Halls A–CA151,000B194,000C128,000473,000 sq ft · mostly 30 ft ceiling39 enclosed docks · trucks at 7th & M St3 drive-ins 25×15 ft · 2 overhead 19×15 ftFloor load 350 lb/sq ft, every hallFloor boxes on a 30 ft gridMarriott Marquis · 1,175 roomsUnderground concourse under 9th St
  • Hall division
  • High ceiling, 40 ft and up

Schematic, not to scale. Levels are stacked to show what sits where; hall footprints and their positions under the street grid are not drawn. Figures from the Events DC floor plan book and exhibitor services page. Official floor plans are on Events DC's floor plan book.

Recent and upcoming show floor plans

An official floor plan from the organizer of a show at the Walter E. Washington Convention Center. Every show draws its own layout, aisles and booth numbers, so use it to see how a real show fills the halls, then work from your own show's plan.

The link goes to the organizer's floor-plan system and opens outside this site. Checked October 16, 2026; plans change as booths sell.

Walter E. Washington exhibit halls, hall by hall
HallLevelAreaCeilingDocksTruck entrance
ALower (L)151,000 sq ft30 ft (12 ft zone on south side)39 enclosed7th & M Street
BLower (L)194,000 sq ft30 ft
CLower (L)128,000 sq ft30 ft
DLevel 2111,000 sq ft40 ft – 52 ft 9 in10 covered9th & M Street
ELevel 2119,000 sq ft40 ft – 52 ft 9 in10 covered
  • A–C473,000 sq ft · ~2,500 booths
  • A+B345,000 sq ft
  • B+C322,000 sq ft
  • D–E230,000 sq ft · ~1,000 booths

From the Events DC floor plan book (dated 2011, still posted by Events DC). Booth counts are maximum 10×10 layouts. A 2024 Freeman exhibit-hall sheet for Halls A and B confirms the 30 ft ceiling, 90 ft column spacing and 350 lb floor load.

2.3 millionsq ft building, owned and operated by Events DC
77meeting rooms, from small breakouts to rooms of 12,500 sq ft
52,000sq ft Ballroom A–C on Level 3, 40 to 48 ft high, with a 20,000 sq ft kitchen next door
40,000sq ft East and West Salons at street level, 18 ft ceilings, beside the grand lobby
30 ftgrid of floor boxes in the halls, with power, voice and data; some add water and compressed air
Washington at night from the air, with the lit Capitol, Washington Monument and Lincoln Memorial along the dark National Mall
Washington at night: the Capitol, Washington Monument and Lincoln Memorial. Photo: Carol M. Highsmith, Library of Congress, public domain.
Only at the WEWCC

Can I build my own booth at the WEWCC? Self-install checker

Washington's convention center is a union floor, but what your own staff may do depends on the show's general service contractor. A 2026 Shepard kit lets exhibitors' full-time staff handle only hand-carried material in their own booth, with no power tools. GES rules for AUSA 2024 let full-time employees set up and take down booths of any size. Answer five questions to see where your booth falls, then confirm in your kit.

Does assembly require power tools?
Is your booth larger than 10×10 (100 sq ft)?
Is it an island or peninsula booth (not a simple inline)?
Does it need rigging or overhead power?
Will only full-time employees of your company do the work?
Your booth Likely self-install

A 10×10 inline booth with no power tools, no rigging and no overhead power, built by your full-time staff, fits even the strictest DC kit we found, as long as it goes in by hand carry.

Plan the build with us

Based on the WMCCAI 2026 move-in guidelines (Shepard; Teamsters 639, Carpenters 491, IATSE 22, IBEW 26) and GES work rules for AUSA 2024 at this building. Our older guide used a 10×10, no-power-tools exemption; we could not find it in a current kit, so size now shows as "check your kit". Your show's kit is the final word.

Insider tips

Walter E. Washington Convention Center exhibitor tips: what experienced teams do

Docks

Put the right corner on the bill of lading

Halls A–C load at 7th & M Street and Halls D–E at 9th & M. A truck at the wrong entrance has to loop the one-way M Street route again.

Height

Take tall builds to D or E

Halls A–C are mostly 30 ft, with a 12 ft zone on the south side of Hall A. Halls D and E rise from 40 ft to 52 ft 9 in, with a 180 ft clear span.

Labor

Leave the drill at home

Under the 2026 Shepard kit, power tools belong to Carpenters Local 491. If your booth needs a drill or impact driver, order labor for that step.

Hand carry

Plan one-trip loads

Hand carry means one person, one trip, one item, no carts, through the 9th & Mt Vernon Place entrance. Pack small boxes you can actually carry.

Power

Map your floor box

Floor boxes sit on a 30 ft grid with power, voice and data. Ask where the nearest box lands in your space before you place counters and screens.

Hotels

Stay at the Marquis in bad weather

The Marriott Marquis is the only hotel linked by an underground concourse. In January Auto Show season or summer storms, that tunnel saves a wet walk.

Loading dock & move-in

Walter E. Washington Convention Center loading dock and freight

Get directions to Walter E. Washington Convention Center →

  • Two dock entrancesHalls A, B and C use the dock entrance at 7th & M Street; trucks wait in the M Street south curb lane. Halls D and E use 9th & M Street; trucks wait on northbound 9th Street.
  • One-way flowTrucks enter eastbound on M Street and leave westbound on M Street to 9th Street. Dock access runs 6 a.m. to 9 p.m. daily, subject to the contractor's receiving schedule.
  • Docks and doors39 enclosed docks serve Halls A–C, with three 25 × 15 ft drive-in doors and two 19 × 15 ft overhead doors. Halls D and E have 10 covered docks each, with drive-ins of 16 × 15 ft (D) and 20 × 15 ft (E).
  • Short dock windowsAt IMS 2024, Freeman gave exhibitors 15-minute dock slots to load and unload. Events DC's transportation team runs the docks and show management must post a dockmaster.
  • Your own vehicleAt WMCCAI 2026, personal vehicles checked in on M Street near 7th, got a dock number, and union crews unloaded them. No personal vehicles on the exhibit floor.
  • Hand carryOne person, one trip, one item, no dollies or wheeled carts, through the 9th & Mt Vernon Place entrance (WMCCAI 2026). Events DC allows what you can carry in one trip.
  • Floor load350 lb per sq ft in every exhibit hall; 100 lb per sq ft in the ballroom and street-level spaces.
  1. Day −60Design approved. Run the self-install checker above, then order electrical, rigging and labor in your kit.
  2. Day −45Booth plans to show management; covered or multilevel booths need DC fire marshal review.
  3. Day −30EAC form and certificate of insurance filed if you hire your own installer.
  4. Day −21Purple ships to Washington through our carrier network, to the advance warehouse or straight to the show.
  5. Day 0Trucks to 7th & M (Halls A–C) or 9th & M (D–E). Teamsters move freight to your booth; union crews build what your kit assigns them.
  6. Show +1Move-out. Turn in the MHA at the service desk, get a dock pass, and wait for your carrier's slot.

Labor & rules of the floor

Walter E. Washington Convention Center labor rules: rules of the floor

All work inside the building falls under local union agreements. A 2026 kit spells out the split: Teamsters Local 639 handle freight, forklifts, pallet jacks and dollies; Carpenters Local 491 build and dismantle booths and run power tools; IATSE Local 22 handle lighting, truss and rigging; IBEW Local 26 make electrical connections. What your own full-time staff may do differs by contractor, so read the labor page of your kit first.

✓Your own team

  • Hand-carry material to your booth: one person, one trip, one item, no carts (2026 kit)
  • Unpack and place products and literature
  • Set up and take down a booth of any size with full-time employees, where the kit allows it (GES, AUSA 2024)
  • Hire your own installer as an EAC, with the kit's paperwork and insurance

●Center-exclusive services

  • Freight from dock to booth: the show's contractor and Teamsters
  • Electrical: IBEW Local 26 connects power from the floor boxes
  • Rigging, truss and lighting: IATSE Local 22
  • Booth and hall cleaning: Aramark Facility Services, exclusive; decorators and EACs may not clean
  • Electrical, plumbing, technology and catering come from Events DC's service partners

!Not allowed

  • Power tools in the hands of your own staff, under the 2026 kit
  • Personal vehicles on the exhibit floor
  • Storing flammable or combustible materials, liquids or gases anywhere in the building
  • Booth sound over 55 dB without approval
  • Fueling display vehicles inside; batteries must be off and tanks at a quarter or 5 gallons
  • Tipping union crews

Background photo: "2014 Washington Auto Show" by BrianBoardman, CC BY 2.0 Source

Free tool · plan your Washington budget

Walter E. Washington Convention Center drayage and show budget estimator (WEWCC)

Pick a booth size and type to get planning numbers for shipping weight, drayage at about $175 per hundredweight, and installation and dismantling (I&D) labor. Every number is a Purple planning estimate, not a quote. We found no published 2026–27 drayage tariff for this building, so $175 is Purple's planning rate for a union city; your show's contractor sets the real one. Events DC publishes no labor rate. See all venues on the drayage rates page.

Booth size
Booth type

The fields below fill in from size and type. Change any of them.

Packaging

Purple planning estimate · not a quote

Drayage + I&D labor, Washington

$5,360 – $8,950
Shipping weight planning estimate
1,800 lbs
Drayage planning estimate
$3,150
I&D labor hours planning estimate
16 – 28 hrs
I&D labor planning estimate
$2,210 – $5,800

18 cwt at $175 per 100 lbs. Labor at $138–$207 per hour, straight time.

Get a real Washington quote

How these planning numbers work

  • Shipping weight: about 6 lbs per sq ft for a rental booth, 9 for custom or hybrid, 12 for fully custom, crated, with graphics and furniture.
  • Drayage: $175 per 100 lbs (cwt), Purple's planning rate for this building, since no current tariff is published. Kits usually add a minimum per shipment and surcharges for late, direct-to-show off-target, overtime or special-handling freight; shipping to the advance warehouse on time usually costs less. Loose or pad-wrapped freight adds 30%.
  • I&D labor hours: install plus dismantle, 0.06–0.10 person-hours per sq ft for rental, 0.08–0.14 for custom or hybrid, 0.12–0.20 for fully custom.
  • Labor rate: $138–$207 per person-hour, straight time, a planning range from published 2026 show labor rates elsewhere. No rate is published for this building, and union overtime costs more.
  • Own staff: only where your kit allows it (see the checker above). Tick the box and I&D labor drops to $0 here; electrical and rigging labor still apply.
  • Not included: booth space, the exhibit itself, freight to Washington, electrical and rigging labor, internet, cleaning, travel and tax.
The 2014 Washington Auto Show floor seen from above, with rows of new cars, brand signs and visitors among the hall columns

On the floor at the 2014 Washington Auto Show

Every winter the Washington Auto Show fills the lower halls with new models, brand islands and public crowds.

Photo: "2014 Washington Auto Show" by Bob Klannukarn, CC BY-SA 2.0 Source

The calendar

Walter E. Washington Convention Center events 2026–2027: trade and consumer shows at the WEWCC

Washington's calendar runs heavy on science, government, defense, space and policy-adjacent industries, with the Washington Auto Show as the big public show each winter. Confirm dates, halls and contractor with each organizer.

Dates from each organizer: SfN, NAEYC, the Washington Auto Show, SATELLITE, Terrapinn and CloserStill Media. AUSA's Annual Meeting & Exposition, which filled five halls with more than 750 exhibits in October 2026, is listed for October 2027 by third parties; we could not confirm it on ausa.org. Data Center World, held here in April 2026, moves to Nashville in 2027.

Where to stay, transit & crew logistics

Hotels near the Walter E. Washington Convention Center

The 1,175-room Marriott Marquis connects to the center by an underground concourse under 9th Street NW. The rest of downtown's big hotels sit a few blocks south, toward Mount Vernon Square, Chinatown and CityCenterDC. For crews, Metro stops at the front door and the docks are on M Street at the back.

Hotels near the Walter E. Washington Convention Center, plotted by straight-line distance and directionMap centred on the Walter E. Washington Convention Center (building map point), north up, distance rings at 0.25 and 0.5 miles. 1. Marriott Marquis Washington, DC: about 0.14 miles southwest, underground concourse. 2. The Westin Washington, DC Downtown: about 0.25 miles south. 3. Embassy Suites by Hilton Washington DC Convention Center: about 0.29 miles southwest. 4. Conrad Washington DC: about 0.30 miles southwest. 5. Grand Hyatt Washington: about 0.44 miles southwest. Pins closer than 0.09 miles are pushed out so they can be read. Positions are from OpenStreetMap coordinates; streets and walking routes are not drawn.0.25 mi0.5 miN00.25 mi≈ 1,320 ftSTRAIGHT-LINENOT A ROUTEWalter E.Washingtonbuilding map point1Marriott Marquis2Westin3Embassy Suites4Conrad5Grand Hyatt
Straight-line positions from OpenStreetMap; walking routes, streets and the underground concourse are not drawn.
Nearby hotels, closest first
Map numberHotelRoomsLink to centerStraight-lineWalk (est.)
2The Westin Washington, DC Downtown999 9th Street NW—Not stated0.25 mi1,340 ft≈ 7 min
3Embassy Suites by Hilton Washington DC Convention Center900 10th Street NW—Not stated0.29 mi1,510 ft≈ 7 min
4Conrad Washington DC950 New York Avenue NW—Not stated0.30 mi1,590 ft≈ 8 min
5Grand Hyatt Washington1000 H Street NW—Not stated0.44 mi2,320 ft≈ 11 min

Distance: straight line from the convention center's map point, the middle of a building that spans several city blocks, so the entrance you use may be closer or farther. Walk: an estimate, straight-line, at 20 minutes a mile plus 30% for streets; not a measured route. "Underground concourse": the Marriott Marquis connects to the convention center under 9th Street NW. "Not stated": no covered link found. Rooms: Marriott Marquis from its public record; "—" where we found no source. Full-service hotels only; several select-service hotels nearby are not listed.

Underground concourse

Marriott Marquis Washington, DC

1,175 rooms, opened in 2014 as the convention center's headquarters hotel, linked below 9th Street.

Green · Yellow lines

Mt Vernon Sq/7th St–Convention Center

The Metro station sits at the building's front door; Gallery Place–Chinatown is a few blocks south.

~3.8 mi

Reagan National (DCA)

The closest airport, about 3.8 miles away in a straight line, with Metro service into downtown.

~24 mi · ~27 mi

Dulles (IAD) and BWI

Dulles is about 24 miles and BWI about 27 miles away, straight-line, for more international and low-cost routes.

The building

Walter E. Washington Convention Center history and the art collection

The center opened in 2003 as the Washington Convention Center, replacing a 1982 hall a few blocks south, and took the name of Walter E. Washington, the city's first home-rule mayor, in 2006. Inside hangs the largest public art collection in DC outside a museum, which Events DC values at $6 million.

A busy exhibit floor in Hall A of the Walter E. Washington Convention Center, crowded with visitors among white-walled booths and tall banners
A full exhibit floor in Hall A. “Exhibit floor, Hall A” by runneralan2004, CC BY 2.0. Source
Black-and-white view of Lingua by Jim Sanborn, a tall cylinder covered in cut-out letters and characters from many languages
Jim Sanborn's Lingua, from the center's public art collection. “'Lingua' by Jim Sanborn” by dbking, CC BY 2.0. Source
Looking down into the curving main lobby and atrium of the Marriott Marquis Washington DC from an upper corner
The atrium lobby of the Marriott Marquis, the connected headquarters hotel, in 2014. “looking down from SW corner at main lobby - Washington Marriott Marquis - Washington DC - 2014” by Tim Evanson, CC BY-SA 2.0. Source
Tall I Love Libraries banners lit in pink, yellow and blue along a convention center concourse during the National Book Festival
I Love Libraries banners on the concourse at the 2023 National Book Festival. “20230812SM0051” by Library of Congress Life, CC0. Source
  1. 1982The first Washington Convention Center opens on December 10 at 909 H Street NW, with 800,000 sq ft.
  2. 2003The new Washington Convention Center opens at Mount Vernon Square, 2.3 million sq ft designed by tvsdesign with Devrouax & Purnell and Mariani and Associates.
  3. 2004The old center is imploded on December 18.
  4. 2006The D.C. Council names the building for Walter E. Washington, the city's first home-rule mayor.
  5. 2009The center hosts inaugural balls, as it did in 2005, and later the 2010 Nuclear Security Summit.
  6. 2014The 1,175-room Marriott Marquis opens next door, linked by an underground concourse.
  7. 2024The NATO summit meets here, after the 2022 U.S.–Africa Leaders Summit.
  8. TodayThe building holds LEED Platinum certification and uses the address 801 Allen Y. Lew Place NW, which replaced 801 Mount Vernon Place NW.

FAQ

Walter E. Washington Convention Center FAQ for exhibitors

Can I set up my own booth?

It depends on the show's contractor. Some DC kits (GES for AUSA 2024) let full-time employees set up booths of any size. Others (Shepard for WMCCAI 2026) allow only hand-carried, no-power-tool work by full-time staff. Rigging and electrical always need union crews. Use the checker above and read your kit.

Is the Walter E. Washington Convention Center union?

Yes. All work inside falls under local union agreements: Teamsters Local 639 for freight, Carpenters Local 491 for booth building, IATSE Local 22 for rigging and lighting, and IBEW Local 26 for electrical, per a 2026 show kit.

How big is the WEWCC?

703,000 square feet of exhibit space across five halls, with 473,000 contiguous square feet in Halls A, B and C on the lower level and 230,000 in Halls D and E on Level 2. The whole building is about 2.3 million sq ft.

How much is drayage?

Purple's planning estimate is about $175 per hundredweight in 2026 and 2027, with a minimum per shipment; ship to the advance warehouse on time to avoid direct-to-show surcharges. Your show kit sets the real rate.

Where are the loading docks?

On M Street. Halls A, B and C use the dock entrance at 7th & M Street (39 enclosed docks); Halls D and E use 9th & M Street (20 covered docks). Trucks enter eastbound on M Street.

What is the ceiling height?

Mostly 30 ft in Halls A–C, with a 10,000 sq ft area at 12 ft on the south side of Hall A. Halls D and E run from 40 ft to 52 ft 9 in. The ballroom is 40 to 48 ft.

Is there a connected hotel?

Yes, the 1,175-room Marriott Marquis Washington, DC connects via an underground concourse across 9th Street NW.

Which airport should I use?

Reagan National (DCA) is closest, about 3.8 miles away in a straight line, with Metro into downtown. Dulles (IAD) is about 24 miles and BWI about 27 miles, with more international and low-cost flights.

Is there Metro access?

Yes, the Mt Vernon Sq/7th St–Convention Center station on the Green and Yellow lines is at the building's front door.

What's the biggest show here?

For the public, the Washington Auto Show, which runs ten days each January (January 22–31 in 2027). On the trade side, AUSA's annual meeting filled five halls with more than 750 exhibits in October 2026.

What is the new address of the convention center?

801 Allen Y. Lew Place NW, Washington, DC 20001. Older kits and maps use the former address, 801 Mount Vernon Place NW.

Where does Purple ship from for Washington shows?

Purple ships and installs from New York and coordinates crews and freight for the Walter E. Washington Convention Center, to the advance warehouse or straight to the show.

Cite the numbers: "The Walter E. Washington Convention Center offers 703,000 square feet of exhibit space across five halls, with 473,000 contiguous square feet in Halls A through C." Purple Exhibits, Walter E. Washington Convention Center Exhibitor Guide, 2026. For a one-page cheat sheet with the hall map, self-install rule, docks and deadlines, print the key numbers, the at-a-glance card and the checker on this page.

Exhibiting at the WEWCC?

Tell us your hall and your contractor.

Send your show, hall and booth number, and the name of the show's contractor. Within two business days you get a self-install eligibility check against that contractor's rules, a design brief that fits a 30 ft or a 50 ft ceiling, a drayage estimate at Washington rates and a move-in plan for the right M Street dock. Purple ships and installs from New York and coordinates crews and freight for the Walter E. Washington Convention Center.

Background photo: "Washington Monument, National World War II Memorial and Capitol at Night" by Maiquel Sampaio, CC BY 2.0 Source

Compare venues

Walter E. Washington Convention Center vs other major U.S. convention centers

How the Walter E. Washington Convention Center stacks up against other major U.S. convention centers. Drayage figures are Purple planning rates, not published tariffs.

VenueTypeLargest spaceCeilingLaborDrayage (plan)Airport
Walter E. Washington Convention CenterThis guideConvention center473,000 sq ft contiguous, Halls A–C30 ft (A–C) · up to 52 ft (D–E)Union · check kit≈ $175/cwtDCA · ~4 mi
America's Center Convention ComplexSt. LouisConvention center574,000 sq ft contiguous, with Dome floor40 ftUnion · 300 sq ft rule≈ $150/cwtSTL · 14 mi
Anaheim Convention CenterAnaheimConvention center221,284 sq ft Hall D25 ft Hall D · 13 ft 8 in Hall EUnion · check kit≈ $172/cwtSNA · 13 mi
Austin Convention CenterAustinConvention center (closed, rebuilding)Closed · 620,000 sq ft rentable from 2029—Right-to-work · venue closed≈ $100/cwtAUS · ~5 mi
Boston Convention & Exhibition CenterBostonConvention center516,000 sq ft contiguous (Halls A–C)35 ft low · up to 100 ftUnion · staff setup OK≈ $324/cwtBOS · 3 mi
Calvin L. Rampton Salt Palace Convention CenterSalt Lake CityConvention center515,000 sq ft contiguous, 10 halls30 ftRight-to-work≈ $120/cwtSLC · ~6 mi
Charlotte Convention CenterCharlotteConvention center280,000 sq ft contiguous, Halls A–C30 ft listed maxRight-to-work≈ $115/cwtCLT · 7 mi
Colorado Convention CenterDenverConvention center584,000 sq ft on one level, Halls A–F30 ft to low steelIATSE 7 · 60-min rule≈ $160/cwtDEN · 30–40 min
Ernest N. Morial Convention CenterNew OrleansConvention center127,364 sq ft Hall E · 1.1M sq ft in all—Right-to-work≈ $155/cwtMSY · 25–30 min
Fontainebleau Las VegasLas VegasResort ballrooms105,264 sq ft Royal Ballroom28 ft 10 inUnion · check kit≈ $185/cwtLAS · 4.3 mi
Gaylord Pacific Resort & Convention CenterChula VistaResort ballrooms140,049 sq ft California Exhibit Hall34 ft hall · 27–28 ft ballroomsCheck show kit≈ $176/cwtSAN · ~10–12 mi
George R. Brown Convention CenterHoustonConvention center547,730 sq ft contiguous, Halls A–E35 ft (Level 1) · 30 ft (Level 3)Right-to-work · check kit≈ $95/cwtHOU · ~9 mi
Georgia World Congress CenterAtlantaConvention center1M+ sq ft contiguous (Halls B, BC, C)30 ft to gridRight-to-work≈ $150/cwtATL · 15–20 min
Hilton AnatoleDallasHotel ballrooms73,000–75,900 sq ft Trinity Exhibit Hall18 ft hall · 28–29 ft ballroomsRight-to-work · check kit≈ $100/cwtDAL · ~4 mi
Hilton New Orleans RiversideNew OrleansHotel ballrooms26,894 sq ft Grand Ballroom18 ft Grand Ballroom · 12 ft Grand SalonRight-to-work · check kit≈ $155/cwtMSY · ~25 min
Hilton OrlandoOrlandoHotel ballrooms48,167 sq ft Orlando Ballroom26 ft Orlando · 24 ft Orange · 18 ft FloridaRight-to-work≈ $155/cwtMCO · 11 mi
Huntington PlaceDetroitConvention center623,000 sq ft contiguous, Halls A–D30 ft (A–D) · 18 ft 8 in (E)Union · 400 sq ft rule≈ $155/cwtDTW · 20 mi
Hyatt Regency OrlandoOrlandoHotel ballrooms54,638 sq ft Regency Ballroom31 ft Regency (listed) · 21 ft PlazaRight-to-work≈ $155/cwtMCO · 12 mi
Indiana Convention CenterIndianapolisConvention center566,600 sq ft contiguous, Halls A–K35 ftUnion · own staff OK≈ $135/cwtIND · ~15 min
Iowa Events CenterDes MoinesConvention center150,000 sq ft contiguous, EMC Expo Center Halls A–C35 ft (Halls B–C)Right-to-work≈ $100/cwtDSM · ~10 min
Javits CenterNew YorkConvention center~500,000 sq ft contiguous (Level 3)Varies by hall · check planUnion · 250 sq ft rule≈ $195/cwtEWR / LGA / JFK · 45–70 min
Kansas City Convention CenterKansas CityConvention center388,800 sq ft column-free, Bartle Hall A–E33 ft A–C · 42 ft D–EIATSE 31 · check kit≈ $145/cwtMCI · ~19 mi
Kay Bailey Hutchison Convention Center DallasDallasConvention center304,250 sq ft open in Halls A–C (2026)35 ft (A, B) · 31–37 ft (C)Right-to-work · check kit≈ $100/cwtDAL · ~6 mi
Los Angeles Convention CenterLos AngelesConvention center346,890 sq ft South Hall G–K40 ft South · 36 ft WestUnion · check kit≈ $175/cwtLAX · ~20 mi
Manchester Grand Hyatt San DiegoSan DiegoHotel ballrooms34,000 sq ft Grand Hall~14 ft Grand Hall · 18–21 ft ballroomsUnion dock · check kit≈ $176/cwtSAN · 3 mi
Marriott Marquis San Diego MarinaSan DiegoHotel ballrooms35,631 sq ft Marriott Grand and Pacific ballrooms26 ft Grand · 16 ft PacificUnion · check kit≈ $176/cwtSAN · 3 mi
McCormick PlaceChicagoConvention center840,000 sq ft Hall A (South) · 1.2M+ on one levelVaries by hall · check planUnion · staff setup any size≈ $210/cwtMDW · ~20 min
Miami Beach Convention CenterMiami BeachConvention center491,654 sq ft contiguous, Halls A–D—Union · IATSE/IBEW · check kit≈ $170/cwtMIA · ~12 mi
Minneapolis Convention CenterMinneapolisConvention center376,200 sq ft contiguous, Halls B–E30 ft 6 in to truss · 85 ft domesUnion · open dock≈ $150/cwtMSP · ~20 min
Moscone CenterSan FranciscoConvention center502,440 sq ft contiguous, Halls A–F37 ft Halls A–C · 28 ft Hall FUnion · check kit≈ $180/cwtSFO · 25–40 min
Oklahoma City Convention CenterOklahoma CityConvention center200,730 sq ft continuous, up to 4 halls30 ftRight-to-work≈ $105/cwtOKC · ~9–10 mi
Orange County Convention CenterOrlandoConvention center1,103,538 sq ft West Building30–40 ftRight-to-work≈ $155/cwtMCO · 12 mi
Oregon Convention CenterPortlandConvention center255,000 sq ft Halls A–E30 ftUnion · check kit≈ $150/cwtPDX · MAX ~30 min
Phoenix Convention CenterPhoenixConvention center312,500 sq ft contiguous, lower Halls 1–632 ft lower · 35 ft upperRight-to-work · check kit≈ $140/cwtPHX · ~3 mi
Reliant CenterHoustonConvention center706,000+ sq ft on one level, Halls A–E25–60 ft · avg 30 ftRight-to-work · check kit≈ $116/cwtHOU · ~8 mi
Rosen Centre HotelOrlandoHotel ballrooms35,000 sq ft Grand Ballroom25 ft Grand · 22 ft Executive, JuniorRight-to-work≈ $155/cwtMCO · 12 min
San Diego Convention CenterSan DiegoConvention center525,701 sq ft contiguous, Halls A–H27 ft 4 in A–E · up to 64 ft F–HUnion · check kit≈ $176/cwtSAN · 3 mi
San Jose McEnery Convention CenterSan JoseConvention center143,000 sq ft Halls 1–332 ftUnion · 30 min / 10 ft rule≈ $160/cwtSJC · 4 mi
Santa Clara Convention CenterSanta ClaraConvention center90,014 sq ft Halls A–D28 ft 6 inUnion · check kit≈ $160/cwtSJC · 5–6 mi
Seattle Convention CenterSeattleConvention center205,700 sq ft Arch Halls 4A–4F25 ft Arch · 30 ft SummitUnion · check kit≈ $165/cwtSEA · Link ~40 min
Sheraton Grand Chicago RiverwalkChicagoHotel ballrooms40,003 sq ft ballroom · 35,000 sq ft Riverwalk hall22 ft ballroom · 10 ft 6 in hallUnion · pop-ups ≤ 10×10≈ $225/cwtMDW · 13 mi
Signia by Hilton Orlando Bonnet CreekOrlandoResort ballrooms35,925 sq ft Bonnet Creek Ballroom20 ft Bonnet Creek · 18 ft Waterside, FloridianRight-to-work≈ $155/cwtMCO · 19 mi
Walt Disney World Swan and DolphinLake Buena VistaResort ballrooms110,500 sq ft Atlantic + Pacific halls30 ft Atlantic · 25′8″ PacificRight-to-work≈ $155/cwtMCO · ~20 min

Nearby guides

Other Washington, D.C. and Mid-Atlantic venues

All venue guides →

Written by the Purple Exhibits team. Reviewed for the 2026–2027 season. Figures marked for verification are being confirmed with Events DC. Sources: Events DC (venue page, exhibitor services, floor plan book); the WMCCAI 2026 move-in guidelines; GES work rules for AUSA 2024; Freeman's IMS 2024 exhibit-hall sheet; Wikipedia (Walter E. Washington Convention Center; Washington Marriott Marquis); organizer sites for show dates; Library of Congress Prints & Photographs Division.

All Washington, D.C. venue guides →